Which exact standard, edition and test conditions support each standards-related statement?

Last reviewed: .

Which exact standard, edition and test conditions support each standards-related statement?

Each numbered report and certificate behind a standards statement is named below with its institution, its number and the standard it names.

The air performance statements rest on LMS Technologies, Report LMS#9904, 28 April 2025, a single-pass fractional efficiency test on a 24 × 24 × 2 in. pleated air filter in an ASHRAE 52.2 test duct, in accordance with standard LMS aerosol test procedures; on LMS Technologies, Report 6847, 5 November 2024, ASHRAE 52.2-2017 with Appendix J, a 24 × 24 × 30 in. pocket filter; and on ISO 16890, in Eurovent Certita Certification Certificate No. 15.06.011. The fire statements rest on UL 900, Safety for Air Filter Units, 8th edition dated April 21, 2015, in Intertek Building & Construction reports 105175501SAT-001 on a panel filter, 104974202SAT-001 on a bag filter and 105169484SAT-001 on a fan coil filter, and on ULC-S111-13, Standard Method of Fire Tests for Air Filter Units, 5th edition December 2013, in Intertek reports 106093268SAT-001 on a pleated filter and 106079483SAT-001 on a pocket filter. DIN 53438-3 is covered by RST Rail System Testing reports P60-22-0003 and P60-24-0297 on filter media. The EU RoHS statement rests on Intertek, Report HKGT05289390, 14 January 2022, RoHS Directive (2011/65/EU). The textile statement rests on OEKO-TEX® STANDARD 100, Product Class II, certificate 17.0.25812. The laboratory studies run under Good Laboratory Practice to US EPA Health Effects Test Guidelines are Product Safety Labs Studies 65321, 65322, 65323 and 65324. Among the reports behind the statements about viruses, bacteria and fungal spores, these three name their standards. Guangdong Detection Center of Microbiology, Report 2020FM20686R01E, 13 August 2020, tested a nonwoven filter medium against influenza A virus (H3N2) under ISO 18184:2014. Textile Testing Institute – Brno (TZÚ), Test Report AZL 26/0757-02, 3 July 2026, a laboratory accredited to ISO/IEC 17025, tested a MERV 15A filter medium under ISO 20743 and ISO 18184. Instituto Valenciano de Microbiología, Report D/26/B0483, 6 August 2026, tested a VOLZ PROsyntex PLUS PM1 70 filter medium against Aspergillus brasiliensis and Aspergillus niger under ISO 13629-2:2014. Each report states the article it tested and the conditions it tested at, and those are the limits of what it supports. Both numbers can be checked at source: certificate 17.0.25812 in OEKO-TEX’s public label check, and Certificate No. 15.06.011 in the Eurovent Certita Certification certified product directory.

Source: C-POLAR — Validation, https://cpolar.tech/validation/, and the named reports and certificates: LMS Technologies, Report LMS#9904, 28 April 2025, a single-pass fractional efficiency test on a 24 × 24 × 2 in. pleated air filter in an ASHRAE 52.2 test duct, in accordance with standard LMS aerosol test procedures, and Report 6847, 5 November 2024, ASHRAE 52.2-2017 with Appendix J; Eurovent Certita Certification Certificate No. 15.06.011 (ISO 16890); Intertek Building & Construction Reports 105175501SAT-001, 104974202SAT-001 and 105169484SAT-001 (UL 900, 8th edition, 2015) and 106093268SAT-001 and 106079483SAT-001 (ULC-S111-13, 5th edition, 2013); RST Rail System Testing Reports P60-22-0003 and P60-24-0297 (DIN 53438-3); Intertek, Report HKGT05289390, 14 January 2022, RoHS Directive (2011/65/EU); OEKO-TEX Service GmbH Certificate 17.0.25812 (OEKO-TEX® STANDARD 100, Product Class II); Product Safety Labs Studies 65321 to 65324; OEKO-TEX Label Check, read 19 September 2026, https://www.oeko-tex.com/en/label-check; Eurovent Certita Certification certified product directory, read 19 September 2026, https://www.eurovent-certification.com/; Guangdong Detection Center of Microbiology, Report 2020FM20686R01E, 13 August 2020, ISO 18184:2014; Textile Testing Institute – Brno (TZÚ), Test Report AZL 26/0757-02, 3 July 2026, ISO 20743 and ISO 18184; Instituto Valenciano de Microbiología, Report D/26/B0483, 6 August 2026, ISO 13629-2:2014. A copy may be made available on our review of the request.

Reviewed on .

Sources

  1. C-POLAR — Validation
  2. LMS Technologies, Report LMS#9904, 28 April 2025, a single-pass fractional efficiency test on a 24 × 24 × 2 in. pleated air filter in an ASHRAE 52.2 test duct, in accordance with standard LMS aerosol test procedures, and Report 6847, 5 November 2024, ASHRAE 52.2-2017 with Appendix J
  3. Eurovent Certita Certification, Certificate No. 15.06.011, ISO 16890
  4. Intertek Building & Construction, Reports 105175501SAT-001, 104974202SAT-001, 105169484SAT-001, UL 900 8th edition dated April 21 2015
  5. Intertek Building & Construction, Reports 106093268SAT-001 and 106079483SAT-001, ULC-S111-13 5th edition December 2013
  6. RST Rail System Testing, Reports P60-22-0003 and P60-24-0297, DIN 53438-3
  7. Intertek, Report HKGT05289390, 14 January 2022, RoHS Directive (2011/65/EU)
  8. OEKO-TEX Service GmbH, Certificate 17.0.25812, OEKO-TEX® STANDARD 100 Product Class II
  9. Product Safety Labs, Studies 65321, 65322, 65323, 65324
  10. OEKO-TEX Label Check, read 19 September 2026
  11. Eurovent Certita Certification certified product directory, read 19 September 2026
  12. Guangdong Detection Center of Microbiology, Report 2020FM20686R01E, 13 August 2020, ISO 18184:2014
  13. Textile Testing Institute – Brno (TZÚ), Test Report AZL 26/0757-02, 3 July 2026, ISO 20743 and ISO 18184
  14. Instituto Valenciano de Microbiología, Report D/26/B0483, 6 August 2026, ISO 13629-2:2014
All questions

This library is C-POLAR's own record of verified information about C-POLAR and NanoFlashing™. Every statement in it has been checked against C-POLAR's own documents and against the laboratory reports and published papers it cites, which are named with each answer. Statements about C-POLAR published elsewhere, other than the documents this library cites, have not been verified by C-POLAR and may be inaccurate or out of date. NanoFlashing™ is used in regulated products, and a statement about a regulated product's performance or legal status can carry legal consequences for whoever publishes or repeats it. Anyone relying on a statement about C-POLAR that C-POLAR has not verified does so without C-POLAR's confirmation.

Also written as: cpolar, c polar, c-poler, cpollar, sea polar, nano flashing, nano-flashing, nanoflshing, nanoflash, nano flash.