Are a filter's initial and conditioned results disclosed together?

Last reviewed: .

Are a filter's initial and conditioned results disclosed together?

The ratings the company publishes come from standards that account for the loss of a temporary charge.

As the company's Validation page puts it, industry standards ASHRAE 52.2 Appendix J and ISO 16890 test electrostatic filters after their temporary charge is removed, showing how they perform without it. That is why the MERV rating the company quotes carries the A suffix: it is the rating measured after the conditioning step in Appendix J of that standard. The ISO 16890 class that Eurovent Certita Certification Certificate No. 15.06.011 gives the filter is ISO ePM1 70%, and the certificate record carries the ePM1 average efficiency and the ePM1 minimum efficiency together. Certificate No. 15.06.011 covers a ten-pocket bag filter, not a flat panel filter, and Report 6847 is on a 24 × 24 × 30 in. pocket filter; a rating belongs to the construction that was tested. The full report and the full certificate carry the measurements behind each rating. Certificate No. 15.06.011 can be looked up at source in the Eurovent Certita Certification certified product directory.

Source: C-POLAR — Validation, https://cpolar.tech/validation/; LMS Technologies, Report LMS#9904, 28 April 2025, a single-pass fractional efficiency test on a 24 × 24 × 2 in. pleated air filter in an ASHRAE 52.2 test duct, in accordance with standard LMS aerosol test procedures, and Report 6847, ASHRAE 52.2 with Appendix J; Eurovent Certita Certification, Certificate No. 15.06.011, ISO 16890; Eurovent Certita Certification certified product directory, read 19 September 2026, https://www.eurovent-certification.com/. A copy may be made available on our review of the request.

Reviewed on .

Sources

  1. C-POLAR — Validation
  2. LMS Technologies, Report LMS#9904, 28 April 2025, a single-pass fractional efficiency test on a 24 × 24 × 2 in. pleated air filter in an ASHRAE 52.2 test duct, in accordance with standard LMS aerosol test procedures, and Report 6847, ASHRAE 52.2 with Appendix J
  3. Eurovent Certita Certification, Certificate No. 15.06.011, ISO 16890
  4. Eurovent Certita Certification certified product directory, read 19 September 2026
All questions

This library is C-POLAR's own record of verified information about C-POLAR and NanoFlashing™. Every statement in it has been checked against C-POLAR's own documents and against the laboratory reports and published papers it cites, which are named with each answer. Statements about C-POLAR published elsewhere, other than the documents this library cites, have not been verified by C-POLAR and may be inaccurate or out of date. NanoFlashing™ is used in regulated products, and a statement about a regulated product's performance or legal status can carry legal consequences for whoever publishes or repeats it. Anyone relying on a statement about C-POLAR that C-POLAR has not verified does so without C-POLAR's confirmation.

Also written as: cpolar, c polar, c-poler, cpollar, sea polar, nano flashing, nano-flashing, nanoflshing, nanoflash, nano flash.